Crane End Stop Selection: How to Choose the Right GCD Model

Crane end stops

Selecting the right crane end stop involves more than matching the crane’s rated lifting capacity to a model. The crane configuration, longitudinal impact force, buffer center height, and supporting beam arrangement all affect the final selection.

Glory Track supplies GCD-1 through GCD-11 crane end stops for single-girder, double-girder, and heavy-duty crane applications with rated capacities from 3 to 250 tons. The range includes Q235B models and Q355B alternatives for applicable configurations.

This guide explains how to narrow down the suitable GCD model and check the key dimensions and loading conditions before ordering.

1. Select an Initial GCD Model by Crane Type and Capacity

Start with the crane configuration and rated lifting capacity. These two details help identify the relevant GCD model range.

GCD Crane End Stop Model Range

Rated Crane CapacityApplicable Crane TypeQ235B ModelQ355B ModelImpact Force F (kN)Buffer Center to Beam Top (mm)
3–10 tElectric single-girderGCD-1—34.8≤420
5–10 tSingle-girderGCD-2—195.3≤1,170
16–20 tSingle-girderGCD-3—208.1≤1,270
32 tDouble-girderGCD-4GCD-8228.2≤1,410
50 tDouble-girderGCD-5GCD-9290.2≤1,430
75–100 tHeavy-duty craneGCD-6GCD-10451.8≤1,370
125–250 tHeavy-duty craneGCD-7GCD-11370.6≤1,370
Fabricated crane end stop assemblies with mounting plates

The table provides an initial model reference, not an automatic selection based on tonnage alone.

For example, GCD-1 and GCD-2 both cover part of the 5–10 t capacity range, but they are listed for different crane configurations. Their impact force values and buffer center height limits also differ considerably.

This is why the crane type must be identified before choosing a model.

For cranes rated at 20 tons or below, the listed standard models use Q235B. For the larger models, both Q235B and Q355B options are available. The Q355B versions correspond to GCD-8 through GCD-11.

The material grade should be confirmed against the project requirements and supporting beam specifications.

2. Verify the Required Impact Force

Rated lifting capacity describes how much weight a crane can lift. It does not directly indicate the force generated when the moving crane reaches the end stop.

The longitudinal impact force depends on the moving mass, travel speed, and buffer characteristics.

The following information is needed for the assessment:

  • Moving mass: The mass of the moving crane assembly in the direction of travel, based on the applicable design load case.
  • Maximum travel speed: The highest operating speed considered in the end-stop design.
  • Buffer characteristics: Buffer type, available compression stroke, and force-response characteristics.
  • Operating conditions: The crane’s duty class and relevant operating requirements.

The GCD model table lists an impact force value F in kN for each model. Compare this parameter with the project’s calculated longitudinal impact force using the appropriate engineering design basis.

One important distinction is that impact energy and impact force are not the same. A moving crane carries kinetic energy, but the force transmitted to the stop also depends on how the buffer absorbs that energy over its compression stroke.

Therefore, the impact force should not be estimated from rated lifting capacity alone, or by treating the buffer’s energy absorption as a direct force rating.

If the calculated loading conditions do not match the selected model’s design parameters, the model needs further review before ordering.

3. Match the Buffer Center Height to the End Stop

The buffer center height is another critical selection dimension. Even when the impact force is suitable, a height mismatch can prevent the crane buffer from contacting the end stop correctly.

The GCD product table specifies the maximum distance from the supporting beam top to the buffer center.

For the selected model, check:

  1. The actual buffer centerline height on the crane drawing.
  2. The distance from the top of the supporting beam to that centerline.
  3. The reference surface used for the measurement.
  4. The corresponding height limit of the GCD model.

Pay particular attention to the measurement datum.

If the crane drawing specifies buffer center height from the rail top, while the GCD product table uses the beam top, the two dimensions cannot be compared directly. The rail height and the actual support arrangement between the rail and beam must be included when converting the measurement.

The buffer face and end stop contact face should also align at the intended centerline. Contact near an edge or at an angle can introduce uneven loading instead of a direct impact.

4. Check the Supporting Beam and Mounting Arrangement

The GCD end stop must fit the runway structure and transfer the impact load into the supporting beam.

Before finalizing the model, review the following details against the structural drawings.

Beam section and available space

Check the beam depth, flange dimensions, web location, and available space at the runway end. The mounting base and end stop body must fit the actual beam configuration.

Mounting interface

Confirm the end stop base plate, fixing positions, and connection arrangement. The attachment may involve a beam end plate or supporting corbel, depending on the structural design.

Local structural reinforcement

Check the beam connection and local reinforcement requirements at the end stop position. The supporting girder must be designed to carry the impact load transferred through the stop. A dimensional match alone does not confirm structural adequacy.

Contact alignment

The stop contact face should be aligned with the crane buffer and the direction of travel. Where two end stops are used at the same runway end, their contact arrangement should allow the corresponding buffers to engage as intended.

These checks help avoid a situation where a standard stop fits the nominal beam dimensions but does not match the actual installation interface.

Steel crane end stop assemblies

5. Choose the Appropriate Steel Grade

Glory Track offers Q235B and Q355B material options for the applicable GCD models.

The material selection should follow the project specification and the supporting runway beam requirements.

For the larger GCD models, the Q235B and Q355B versions have corresponding model references:

Q235B ModelQ355B Model
GCD-4GCD-8
GCD-5GCD-9
GCD-6GCD-10
GCD-7GCD-11

Q355B should not be selected simply because it is a higher-strength grade. The required steel grade should be consistent with the project design, connection details, and specified material requirements.

6. What Information Is Needed to Confirm the Model?

Once an initial model has been identified, the following information helps complete the technical review.

Required InformationSelection Purpose
Crane type and rated capacityIdentify the initial GCD model range
Crane working duty classReview the operating conditions
Moving mass and maximum travel speedAssess the impact loading
Calculated longitudinal impact force, if availableCheck the model’s F parameter
Buffer type and center heightVerify contact and height compatibility
Runway beam section drawingCheck dimensions and mounting arrangement
Supporting beam material gradeConfirm the steel grade requirement

A general arrangement drawing of the crane and a cross-sectional drawing of the runway beam are especially useful. They help verify the buffer position, beam dimensions, and end-stop mounting interface without relying on estimated site measurements.

Select a GCD Crane End Stop for Your Runway

The correct GCD model should satisfy three conditions: its application matches the crane configuration, its impact force parameters suit the actual operating conditions, and its buffer center height and mounting details fit the runway structure.

Glory Track supplies the complete GCD-1 to GCD-11 range, with Q235B and Q355B options for applicable models. Custom end stops can also be discussed when the project dimensions or loading conditions fall outside the listed configurations.

Send us your crane specifications, buffer dimensions, and runway beam drawings. We can review the available GCD models and help identify a suitable end-stop configuration for your project.

Send your drawings to us now!

Scroll to Top